CIRS声模体
产品介绍美国原厂进口CIRS声模体040GSE美国原厂进口CIRS声模体040GSE,具有灰阶靶群、消声阶梯块和弹性靶群。该模体是为了满足医用声设备质量保证挑战的需求。的双重衰减背景凝胶允许用户评估MHz - 15 MHz之间的传感器。允许评估有传感器的配置:直线、曲线、内腔。美国原厂进口CIRS声模体040GSE声质量保证模体有坚固的外壳和便携箱、用户指南以及数据表。NewThe CIRS Mo
您的位置:
产品介绍美国原厂进口CIRS声模体040GSE美国原厂进口CIRS声模体040GSE,具有灰阶靶群、消声阶梯块和弹性靶群。该模体是为了满足医用声设备质量保证挑战的需求。的双重衰减背景凝胶允许用户评估MHz - 15 MHz之间的传感器。允许评估有传感器的配置:直线、曲线、内腔。美国原厂进口CIRS声模体040GSE声质量保证模体有坚固的外壳和便携箱、用户指南以及数据表。NewThe CIRS Mo
产品介绍 |
美国原厂进口CIRS声模体040GSE 美国原厂进口CIRS声模体040GSE,具有灰阶靶群、消声阶梯块和弹性靶群。该模体是为了满足医用声设备质量保证挑战的需求。的双重衰减背景凝胶允许用户评估MHz - 15 MHz之间的传感器。允许评估有传感器的配置:直线、曲线、内腔。 美国原厂进口CIRS声模体040GSE声质量保证模体有坚固的外壳和便携箱、用户指南以及数据表。 NewThe CIRS Model 040GSE Multi-Purpose Multi-Tissue Ultrasound Phantom not only contains all the features of the original CIRS Model 040 but also includes gray scale targets anechoic stepped masses and elasticity targets. The phantom is designed to meet the ultrasound QA chal-lenges of today and tomor-row. The unique dual attenuation of the background gel allows for evaluation of transducers that range from 2 MHz - 15 MHz. A removable water well and endocavity cover extends the use of the phantom by al-lowing evaluation of all trans-ducer configurations: linear curvilinear and intercavity. CIRS ultrasound QA phan-toms all come standard with a robust housing rugged carry case 4-year warranty user guide and data sheet. |
Model 040GSE美国原厂进口CIRS声模体040GSE
Exceeds ACR Accreditation Requirements
Performance Measurements
• Dead Zone • Horizontal Distance • Vertical Distance • Depth of Penetration • Image Uniformity • Axial Resolution • Lateral Resolution • Anechoic Mass Resolution • Gray Scale Contrast Resolution • Elasticity Image Evaluation Overall Ultrasound image of Model 040GSE
| HORIZONTAL AND VERTICAL GROUPS: Material: Nylon monofilament Wire diameter: 100 microns VERTICAL GROUP: Number of targets: 15 Wire diameter: 100 microns Depth range: 1 to 16 cm Spacing: 10 mm HORIZONTAL GROUP Number of groups: 2 Wire diameter: 100 microns Depth range: 4 and 9 cm Number of targets: 4 & 7 respectively Spacing: 10 & 20 mm respectively COMBINED AXIAL-LATERAL RESOLUTION GROUPS: Number of groups: 2 Wire diameter: 80 microns Depth range: 3 & 6.5 cm Axial Intervals: 4 3 2 1 0.5 & 0.25 mm | MATERIAL: Zerdine®(1) solid elastic water-based polymer Freezing point: 00 C Melting point: Above 1000 C ATTENUATION COEFFICIENT: 0.5 dB/cm-MHz 0.7 dB/cm-MHz SPEED OF SOUND: 1540 m/s ± 10 m/s SCANNING WELL: 1 cm deep SCANNING MEMBRANE: Saran-based laminate NEAR FIELD GROUP: Material: Nylon monofilament Number of targets: 5 Depth range: 1 to 5 mm Distance between Targets: 1 mm |